Commissioning
If there is an active online connection, you should then activate the "Permanent" tab. "Read" reads the
number of entries of the permanent diagnostic memory specified under "Entries" and displays them in
chronological order, newest first.
Selecting "All entries" reads the complete permanent diagnostic memory. This can take several minutes.
The content of the diagnostic memory is displayed in the form of a table:
Column
No.
Malfunction no.
Malfunction description
Time stamp
Constant
Free parameter
Type
Tab. 4.3 Display of the permanent diagnostic memory
The following table shows some entries as an example:
No.
Malfunc­
Malfunction
tion no.
description
1
00-21
Log entry from the
safety module
2
00-8
Controller switched on
3
00-12
Module change:
Current module
4
00-11
Module change:
Previous module
...
...
...
Tab. 4.4 Sample entries in the diagnostic memory
Additional information on the entries in the diagnostic memory:
– entries are made chronologically, meaning that the top entry is the most recent entry.
– small deviations to the time stamp are possible after Power OFF/ON, as the motor
controller only saves the timestamp once per minute to non-volatile memory.
"Copy" and "Export" can be used to transfer the contents in csv format with ';' delimiters to the Win­
dows clipboard or a file.
The value of the operating hour counter of the motor control at the time of the log entry is displayed in
the "Timestamp" column.
166
Explanation
Sequence number of the entry.
Error, warning or event number è see Section 5.5.3.
Name of the entry, error text.
Time of the diagnostic event in the format <hh>:<mm>:<ss> (operating hour
counter, duty cycle of the logic supply).
Additional information for the Festo service personnel
Additional information for the Festo service personnel
Type of entry (error, warning, log entry).
Time
stamp
580:15:03 0x0000
580:15:00 0x0000
580:15:22 0x4830
580:15:22 0x48FF
...
Con­
Free parameter
stant
Error acknowledge,
source: 0x01, error free
0x0000
CAMC-G-S3, S/N:
1212820487, HW rev.:
1.0, SW rev.: 1.0
CAMC-DS-M1, S/N:
3781764777, HW rev.:
0.1, SW rev.: 0.1
...
...
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English
Type
Error
Error
Error
Error
...