2
Product description of safety module CAMC-G-S3
SSF: Safe speed
Parameter no. for ...
SSF0
SSF1
SSF2
Expert parameter
P0E.0D P0E.21
P0E.35 P0E.49 Speed ramp - Monitoring
P0E.06 P0E.1A P0E.2E
P0E.04 P0E.18
P0E.2C P0E.40 Slowdown ramp - Starting
P0E.05 P0E.19
P0E.2D P0E.41 Slowdown ramp - Starting
P0E.0C P0E.20
P0E.34 P0E.48 Speed limit offset
P0E.0A P0E.1E
P0E.32 P0E.46 Activate quick stop ramp
Tab. 2.56 SSF: Safe speed
102
Name
Name
SSF3
time delay
P0E.42 Slowdown ramp - time
delay to start
value factor
value offset
in the basic unit
Description
Description
The ramp used to monitor the
speed in the safety module is
also delayed compared to the
ramp applied to the basic unit.
Time delay, after which the monit­
oring ramp in the safety module
starts.
Factor for calculating the starting
value of the ramps
Offset for calculating the starting
value of the ramps
Offset for the speed limits for
controlling the basic unit.
If set: When the safety function is
requested, the quick stop com­
mand (pilot line) is applied to the
basic unit