Basic Principles Of Parameterisation Of The Safety Module - Festo CAMC-G-S3 Manual

Safety module
Table of Contents

Advertisement

4
Commissioning
4.4

Basic principles of parameterisation of the safety module

4.4.1
Factory setting
For simplified parameterisation, in the delivery status, or after the factory setting is reset, some func­
tions are activated and standard values are preset.
Tab. 4.5 offers an overview of the most important settings.
Page
Factory setting
Digital inputs
DIN40
Sensor type:
Operating mode:
Discrepancy time:
Source for test pulse: None
DIN 41
Sensor type:
Operating mode:
Discrepancy time:
Source for test pulse: None
DIN 42
Sensor type:
Operating mode:
Discrepancy time:
Source for test pulse: None
DIN 43
Sensor type:
Operating mode:
Discrepancy time:
Source for test pulse: None
DIN 44
Sensor type:
Source for test pulse: None
DIN 45
Sensor type:
Source for test pulse: None
DIN 46
Sensor type:
Source for test pulse: None
DIN 47
Sensor type:
Source for test pulse: None
DIN48
Sensor type:
Source for test pulse: None
DIN 49
Sensor type:
Source for test pulse: None
Safety functions
STO
Request:
Automatic restart:
Automatic activation
of SBC:
Terminate request:
168
Emergency stop switching device
Equivalent
100 ms
Not defined
Equivalent
100 ms
Not defined
Equivalent
100 ms
Not defined
Equivalent
100 ms
Brake feedback
Mode selector switch
Mode selector switch
Mode selector switch
Fault acknowledgment
Terminate safety function
DIN40
No
Yes
DIN49, rising edge
Festo – GDCP-CAMC-G-S3-EN – 1406NH – English
Allocation
STO and SBC request
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Fault acknowledg­
ment request
Rising edge: Termin­
ate STO, SS1 and
SBC

Advertisement

Table of Contents
loading

Table of Contents