Non-Hitless Upgrade: Installs the License Key simultaneously on both devices
where both undergo a reset and therefore, current calls are terminated. When
you click the button, the process starts and the following progress message box
appears:
When installation completes, the following message box appears:
Figure 38-13: Reset and Save-to-Flash Success Message
6.
Clock Close to close the message box; you are logged out of the Web interface and
prompted to log in again. The features and capabilities displayed on the License Key
page now reflect the newly installed License Key.
38.2.2 Installing License Key through CLI
To install the License Key through CLI, use the following commands:
To install the License Key:
(config-system)# feature-key <"string enclosed in double
quotation marks">
To view the License Key:
show system feature-key
38.2.3 Verifying Installed License Key
Once you have finished installing the new License Key, verify that it has been installed:
On the License Key page, check that the listed features and capabilities of the newly
installed License Key match those that you ordered.
Access the Syslog server and check that the following message appears:
"S/N<serial number> Key Was Updated. The Board Needs to be Reloaded with
ini file\n"
If the Syslog server indicates that the License Key was unsuccessfully loaded (i.e., the
"SN_" line is blank), do the following preliminary troubleshooting procedures:
1.
Open the License Key file and check that the "S/N" line appears. If it does not
appear, contact AudioCodes.