# debug capture VoIP physical get_last_capture <TFTP/FTP
server IP address>
The file is saved to the device's memory (not flash) and erased after a device reset.
Marks the captured file (useful for troubleshooting process):
# debug capture VoIP physical insert-pad
Before running this command, the debug capture must be started.
Displays debug status and configured rules:
# debug capture VoIP physical show
Specifies the destination (FTP, TFTP, or USB) where you want the PCAP file sent:
# debug capture VoIP physical target <ftp|tftp|usb>
Stops the debug capture, creates a file named debug-capture-voip-<timestamp>.pcap,
and sends it to the TFTP or FTP server:
# debug capture voip physical stop <TFTP/FTP server IP
address>
If no IP address is defined, the capture is saved on the device for later retrieval.