User's Manual
Parameter
Action
Action Subject
action-subject
[CallSetupRules_ActionSubject]
Action Type
action-type
[CallSetupRules_ActionType]
Action Value
action-value
[CallSetupRules_ActionValue]
Version 7.2
found)
dialplan.result=='uk' (if corresponding tag of the
searched key is "uk")
ENUM:
enum.found exists (if ENUM record of E.164 number
exists)
Defines the element (header, parameter, body, or Dial Plan
tag) upon which you want to perform the action if the condition,
configured in the 'Condition' parameter (see above) is met.
The valid value is a string of up to 100 characters (case-
insensitive).
Examples:
header.from contains '1234'
param.call.dst.user (called number)
param.call.src.user (calling number)
param.call.src.name (calling name)
param.call.redirect (redirect number)
param.call.src.host (source host)
param.call.dst.host (destination host)
srctags (source tag)
dsttags (destination tag)
Defines the type of action to perform.
[0] Add (default) = Adds new message header, parameter
or body elements.
[1] Remove = Removes message header, parameter, or
body elements.
[2] Modify = Sets element to the new value (all element
types).
[3] Add Prefix = Adds value at the beginning of the string
(string element only).
[4] Add Suffix = Adds value at the end of the string (string
element only).
[5] Remove Suffix = Removes value from the end of the
string (string element only).
[6] Remove Prefix = Removes value from the beginning of
the string (string element only).
[20] Run Rules Set = Performs a different Rule Set ID,
specified in the 'Action Value' parameter (below)
[21] Exit = Stops the Rule Set ID and returns a result
("True" or "False"). .
Defines a value that you want to use in the action.
The valid value is a string of up to 300 characters (case-
insensitive).
Examples:
'+9723976'+ldap.attr.alternateNumber