AudioCodes Mediant 4000 SBC User Manual page 138

Session border controller
Hide thumbs Also See for Mediant 4000 SBC:
Table of Contents

Advertisement

2.
Click New; the following dialog box appears:
3.
Configure a static route according to the parameters described in the table below. The
address of the host/network you want to reach is determined by an AND operation that
is applied to the fields 'Destination' and 'Prefix Length'. For example, to reach network
10.8.x.x, enter "10.8.0.0" in the 'Destination' field and "16" in the 'Prefix Length'. As a
result of the AND operation, the value of the last two octets in the 'Destination' field
are ignored. To reach a specific host, enter its IP address in the 'Destination' field and
"32" in the 'Prefix Length' field.
4.
Click Apply, and then reset the device with a save-to-flash for your settings to take
effect.
Note:
Only static routing rules that are inactive can be deleted.
Table 11-14: Static Routes Table Parameter Descriptions
Parameter
Index
[StaticRouteTable_Index]
Description
description
[StaticRouteTable_Description]
Destination
destination
[StaticRouteTable_Destination]
Prefix Length
prefix-length
[StaticRouteTable_PrefixLength]
User's Manual
Defines an index number for the new table row.
The valid value is 0 to 29.
Note: Each row must be configured with a unique index.
Defines a name for the rule.
The valid value is a string of up to 20 characters.
Defines the IP address of the destination host/network. The
destination can be a single host or a whole subnet, depending on
the prefix length configured for this routing rule.
Defines the Classless Inter-Domain Routing (CIDR)-style
representation of a dotted-decimal subnet notation of the
destination host/network. The CIDR-style representation uses a
suffix indicating the number of bits that are set in the dotted-
decimal format. For example, the value 16 represents subnet
255.255.0.0. The value must be 0 to 31 for IPv4 interfaces and a
138
Mediant 4000 SBC
Description
Document #: LTRT-40203

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mediant 4000b sbc

Table of Contents