User's Manual
Warning: If you use the IniFileURL parameter for the Automatic Update feature, do
not use the Web interface to configure the device. If you do configure the device
through the Web interface and save (burn) the new settings to the device's flash
memory, the IniFileURL parameter is automatically set to 0 and Automatic Updates is
consequently disabled. To enable Automatic Updates again, you need to re-load the
ini file (using the Web interface or BootP) with the correct IniFileURL settings. As a
safeguard to an unintended save-to-flash when resetting the device, if the device is
configured for Automatic Updates, the 'Burn To FLASH' field under the Reset
Configuration group in the Web interface's Maintenance Actions page is automatically
set to No by default.
Note:
For a description of all the Automatic Update parameters, see ''Automatic Update
Parameters'' on page
For additional security, use HTTPS or FTPS. The device supports HTTPS (RFC
2818) and FTPS using the AUTH TLS method <draft-murray-auth-ftp-ssl-16>.

41.2.1 Files Provisioned by Automatic Update

You can use the Automatic Update feature to update the device with any of the following
files:
Software file (cmp)
Auxiliary files (e.g., Call Progress Tones, SSL Certificates, SSL Private Key)
Configuration file:
ini File: Contains only ini file parameters and configures all the device's
functionalities, except Data-Routing.
CLI Script File: Contains only CLI commands and configures all the device's
functionalities (except commands such as show, debug or copy). The file updates
the device's configuration only according to the configuration settings in the file.
The device's existing configuration settings (not included in the file) are retained.
The device does not undergo a reset and therefore, this file typically contains
configuration settings that do not require a device reset. If a reset is required, for
example, to apply certain settings, you must include the following CLI command
(root level) at the end of the file:
# reload if-needed
To configure the URL of the server where the file is located, use the
AUPDCliScriptURL ini file parameter or CLI command, configure system >
automatic-update > cli-script <URL>.
Startup Script File: Contains only CLI commands and configures all the device's
functionalities (except commands such as show, debug or copy). The file updates
the device's configuration according to the configuration settings in the file and
sets all other parameters that are not included in the file to factory defaults. The
file causes two device resets to apply the settings. Therefore, the file typically
contains the Automatic Update settings and other configuration settings that
require a device reset. The URL of the server where this file is located is
configured by the AUPDStartupScriptURL ini file parameter or CLI command,
configure system > automatic-update > startup-script <URL>.
Version 7.2
816
or refer to the CLI Reference Guide.