Restoring Factory Defaults

This section describes how to restore the device's configuration to factory defaults.
43.1

Restoring Factory Defaults through CLI

You can restore the device to factory defaults through CLI, as described in the following
procedure.
To restore factory defaults through CLI:
1.
Access the CLI:
a.
Connect the RS-232 serial port of the device to the communication port on your
computer. For serial cabling, refer to the Hardware Installation Manual.
b.
Establish serial communication with the device using a serial communication
program (such as HyperTerminalTM) with the following communication port
settings:
2.
At the CLI prompt, type the username (default is "Admin" - case sensitive), and then
press Enter:
# Username: Admin
3.
At the prompt, type the password (default is "Admin" - case sensitive), and then press
Enter:
# Password: Admin
4.
At the prompt, type the following, and then press Enter:
# enable
5.
At the prompt, type the password again, and then press Enter:
# Password: Admin
6.
At the prompt, type the following to reset the device to default settings, and then press
Enter:
# write factory
Version 7.2
Baud Rate: 115,200 bps
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None