Remotely Resetting Device Using Sip Notify; Locking And Unlocking The Device - AudioCodes Mediant 4000 SBC User Manual

Session border controller
Hide thumbs Also See for Mediant 4000 SBC:
Table of Contents

Advertisement

4.
In the 'Shutdown Timeout' field (available only if the 'Graceful Option' field is
configured to Yes), enter the time after which the device resets. Note that if no traffic
exists and the time has not yet expired, the device resets.
5.
Click the Reset button; a confirmation message box appears, requesting you to
confirm.
6.
Click OK to confirm device reset; if the 'Graceful Option' field is configured to Yes (in
Step 3), the reset is delayed and a screen displaying the number of remaining calls
and time is displayed. When the device begins to reset, a message appears to notify
you.
35.2

Remotely Resetting Device using SIP NOTIFY

The device can be remotely reset upon the receipt of a SIP NOTIFY that contains an Event
header that is set to 'check-sync;reboot=true' (proprietary to AudioCodes), as shown in the
example below:
NOTIFY sip:<user>@<dsthost> SIP/2.0
To: sip:<user>@<dsthost>
From: sip:sipsak@<srchost>
CSeq: 10 NOTIFY
Call-ID: 1234@<srchost>
Event: check-sync;reboot=true
To enable remote reset upon receipt of SIP NOTIFY:
1.
Open the Gateway Advanced Settings page (Setup menu > Signaling & Media tab >
Gateway folder > Gateway Advanced Settings).
2.
From the 'Remote Management by Notify' (EnableSIPRemoteReset) drop-down list,
select Enable:
3.
Click Apply.
35.3

Locking and Unlocking the Device

You can lock the device so that it stops processing calls. This may be useful, for example,
when you want to upload new software files to the device and you don't want any traffic to
interfere with the process. Locking the device may be done gracefully, whereby the device
stops accepting new calls, but allows existing calls to continue for up to a user-defined
duration before terminating them.
To lock the device:
1.
Open the Maintenance Actions page:
Toolbar: Click the Reset button.
User's Manual
Figure 35-2: Resetting Device by SIP NOTIFY
622
Mediant 4000 SBC
Document #: LTRT-40203

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mediant 4000b sbc

Table of Contents