60.1.3 Telnet Parameters

The Telnet parameters are described in the table below.
Parameter
Embedded Telnet Server
configure system > cli-settings
> telnet
[TelnetServerEnable]
Telnet Server TCP Port
configure system > cli-settings
> telnet-port
[TelnetServerPort]
Telnet Server Idle Timeout
configure system > cli-settings
> idle-timeout
[TelnetServerIdleDisconnect]
Maximum Telnet Sessions
configure system > cli-settings
> telnet-max-sessions
[TelnetMaxSessions]
[CLIPrivPass]
Default Terminal Window
Height
configure system > cli-
settings > default-
window-height
[DefaultTerminalWindowHeight]
Version 7.2
Table 60-3: Telnet Parameters
Enables the device's embedded Telnet server. Telnet is disabled by
default for security.
[0] Disable
[1] Enable Unsecured (default)
[2] Enable Secured
Note: Only the primary Web User Account (which has Security
Administration access level) can access the device using Telnet
(see ''Configuring Management User Accounts'' on page 69).
Defines the port number for the embedded Telnet server.
The valid range is all valid port numbers. The default port is 23.
Defines the timeout (in minutes) for disconnection of an idle Telnet
session. When set to zero, idle sessions are not disconnected.
The valid range is any value. The default is 0.
Note: For the parameter to take effect, a device reset is required.
Defines the maximum number of permitted, concurrent Telnet/SSH
sessions.
The valid range is 1 to 5 sessions. The default is 2.
Note: Before changing the value, make sure that not more than this
number of sessions are currently active; otherwise, the new setting
will not take effect.
Defines the password to access the Enable configuration mode in
the CLI.
The valid value is a string of up to 50 characters. The default is
"Admin".
Note: The password is case-sensitive.
Defines the number (height) of output lines displayed in the CLI
terminal window. This applies to all new CLI sessions and is
preserved after device resets.
The valid value range is -1 (default) and 0-65535:
A value of -1 means that the parameter is disabled and the
settings of the CLI command window-height is used.
A value of 0 means that all the CLI output is displayed in the
window.
A value of 1 or greater displays that many output lines in the
window and if there is more output, the "—MORE—" prompt is
displayed. For example, if you configure the parameter to 4, up
to four output lines are displayed in the window and if there is
more output, the "—MORE—" prompt is displayed (at which you
can press the spacebar to display the next four output lines).
Note: You can override this parameter for a specific CLI session
809
60. Configuration Parameters Reference
Description
Mediant 4000 SBC