User's Manual
Periodically:
Specified time of day (e.g., 18:00), configured by the ini file parameter
AutoUpdatePredefinedTime or CLI command configure system > automatic-
update > predefined-time.
Interval between Automatic Updates (e.g., every 60 minutes), configured by the
ini file parameter AutoUpdateFrequency or CLI command configure system >
automatic-update > update-frequency.
Centralized provisioning server request:
Upon receipt of an SNMP request from the provisioning server.
Upon receipt of a special SIP NOTIFY message from the provisioning server. The
NOTIFY message includes an Event header with the AudioCodes proprietary
value, "check-sync;reboot=false", as shown in the example below:
NOTIFY sip:<user>@<dsthost> SIP/2.0
To: sip:<user>@<dsthost>
From: sip:sipsak@<srchost>
CSeq: 10 NOTIFY
Call-ID: 1234@<srchost>
Event: check-sync;reboot=false
To enable the feature:
a.
b.
c.
To enable through CLI: configure voip > sip-definition advanced-settings > sip-
remote-reset.

41.2.6 Access Authentication with HTTP Server

You can configure the device to authenticate itself with the HTTP/S server. The device
authenticates itself by providing the HTTP/S server with its authentication username and
password. You can configure one of the following HTTP authentication schemes:
Basic Access Authentication: The device provides its username and password to
the HTTP server. The username and password is configured in the URL that you
define for downloading the file:
ini file:
AutoCmpFileUrl = 'https://<username>:<password>@<IP address
or domain name>/<file name>'
CLI:
# configure system
(config-system)# automatic update
(automatic-update)# auto-firmware https://<username>:<password>@<IP
address or domain name>/<file name>
Digest Access Authentication: The authentication username and password is
negotiated between the device and HTTP/S server, using digest MD5 cryptographic
hashing. This method is safer than basic access authentication. The digest
authentication username and password are configured using the
AUPDDigestUsername and AUPDDigestPassword parameters, respectively.
Version 7.2
Open the Gateway Advanced Settings page (Setup menu > Signaling &
Media tab > Gateway folder > Gateway Advanced Settings).
From the 'Remote Management by Notify' (EnableSIPRemoteReset) drop-
down list, select Enable:
Figure 41-2: Resetting Device by SIP NOTIFY