sdlc timer poll
Use sdlc timer poll to configure the SDLC polling interval, the amount of time the primary station waits
between polling two secondary stations.
Use undo sdlc timer poll to restore the default.
Syntax
sdlc timer poll mseconds
undo sdlc timer poll
Default
SDLC polling interval is 1000 milliseconds.
Views
Synchronous serial interface view
Default command level
2: System level
Parameters
mseconds: SDLC polling interval in milliseconds. The range is 1 to 10000.
Examples
# Set the SDLC polling interval to 200 milliseconds on Serial 2/0.
<Sysname> system-view
[Sysname] interface serial 2/0
[Sysname-Serial2/0] sdlc timer poll 200
sdlc window
Use sdlc window to configure the maximum number of consecutive frames the device can send before
receiving an acknowledgement from the peer.
Use undo sdlc window to restore the default.
Syntax
sdlc window length
undo sdlc window
Default
The maximum number of consecutive frames the device can send before receiving an acknowledgement
from the peer is 7.
Views
Synchronous serial interface view
Default command level
2: System level
283