Examples
# Configure the operation mode of frame relay interface Serial 2/0 as DTE and set N392 to 5 and N393
to 6.
<Sysname> system-view
[Sysname] interface serial2/0
[Sysname-Serial2/0] link-protocol fr
[Sysname-Serial2/0] fr interface-type dce
[Sysname-Serial2/0] fr lmi n392dce 5
[Sysname-Serial2/0] fr lmi n393dce 6

fr lmi n393dce

Use fr lmi n393dce to set the DCE-side N393 counter.
Use undo fr lmi n393dce to restore the default.
Syntax
fr lmi n393dce n393-value
undo fr lmi n393dce
Default
The DCE-side N393 counter is 4.
Views
Interface view
Default command level
2: System level
Parameters
n393-value: Sets the DCE-side N393 counter in the range of 1 to 10.
Usage guidelines
The DCE requires the DTE to send a Status-Enquiry message at a regular interval (set by T392). If the DCE
does not receive the Status-Enquiry message within a certain period, the error counter on the DCE
increments by one. If the number of errors exceeds the error threshold, the DCE considers the physical
link and all DLCIs unavailable.
The N392 counter sets an error threshold for the total number of monitored events set by the N393
counter. If the number of errors that occur among N393 events reaches the error threshold, the DCE
considers the physical link and all DLCIs unavailable.
N392 must be less than N393 on the DCE side.
Examples
# Set frame relay interface Serial 2/0 to operate in DCE mode, and set N392 to 5 and N393 to 6.
<Sysname> system-view
[Sysname] interface serial2/0
[Sysname-Serial2/0] link-protocol fr
[Sysname-Serial2/0] fr interface-type dce
[Sysname-Serial2/0] fr lmi n392dce 5
[Sysname-Serial2/0] fr lmi n393dce 6
124