Llc2 Timer Reject; Reset Dlsw Circuits - HP MSR series Command Reference Manual

Layer 2 wan
Hide thumbs Also See for MSR series:
Table of Contents

Advertisement

Parameters
mseconds: LLC2 P/F waiting time in milliseconds. The range is 1 to 60000.
Usage guidelines
When a router sends a frame that requires an acknowledgment, the frame is sent with a poll bit set. This
frame is called a "P frame." Once the router sends a P frame, it cannot send any other P frame until it
receives an acknowledgment, or until the LLC2 P/F waiting time expires.
Examples
# Set the LLC2 P/F waiting time to 2000 milliseconds on Ethernet 1/0.
<Sysname> system-view
[Sysname] interface ethernet 1/0
[Sysname-Ethernet1/0] llc2 timer poll 2000

llc2 timer reject

Use llc2 timer reject to configure the LLC2 REJ status timer, the amount of time the router waits for the
expected frame after it receives an unexpected frame and sends a reject frame.
Use undo llc2 timer reject to restore the default.
Syntax
llc2 timer reject mseconds
undo llc2 timer reject
Default
The LLC2 REJ status timer is 500 milliseconds.
Views
Ethernet interface view
Default command level
2: System level
Parameters
mseconds: LLC2 REJ status timer in milliseconds. The range is 1 to 60000.
Examples
# Set the LLC2 REJ status timer to 2000 milliseconds on Ethernet 1/0.
<Sysname> system-view
[Sysname] interface ethernet 1/0
[Sysname-Ethernet1/0] llc2 timer reject 2000

reset dlsw circuits

Use reset dlsw circuits to clear DLSw virtual circuit information.
Syntax
reset dlsw circuits [ circuit-id ]
270