Default
The auto-dial timer of DCC is 300 seconds.
Views
Dialup interface (physical or dialer interface) view
Default command level
2: System level
Parameters
seconds: Interval before the next call attempt, in the range of 1 to 604800 seconds.
Usage guidelines
This command takes effect only when the autodial keyword is configured in the dialer route command.
It allows DCC to automatically dial at certain intervals to set up a connection. In the auto-dial approach,
dial attempts to set up connection are not traffic triggered. Once a connection is set up, it will not
disconnect for idle-timeout. The use of auto-dial thus voids the dialer timer idle command.
Examples
# Set the auto-dial interval of DCC to 60 seconds on interface Serial 2/0.
<Sysname> system-view
[Sysname] interface serial 2/0
[Sysname-Serial2/0] dialer timer autodial 60
Related commands
dialer route

dialer timer compete

Use dialer timer compete to set the compete-idle timer.
Use undo dialer timer compete to restore the default.
Syntax
dialer timer compete seconds
undo dialer timer compete
Default
The compete-idle timer is 20 seconds.
Views
Dialup interface (physical or dialer interface) view
Default command level
2: System level
Parameters
seconds: Idle interval when contention occurs, in the range of 0 to 65535 seconds.
Usage guidelines
If all the channels are unavailable when DCC originates a new call, contention occurs.