Default
The maximum number of consecutive information frames the router can send before receiving an
acknowledgment from the peer is 7.
Views
Ethernet interface view
Default command level
2: System level
Parameters
length: Maximum number of consecutive information frames the router can send before receiving an
acknowledgment from the peer, in the range of 1 to 127.
Examples
# Set the maximum number of consecutive information frames the router can send before receiving an
acknowledgment from the peer to 10 on Ethernet 1/0.
<Sysname> system-view
[Sysname] interface ethernet 1/0
[Sysname-Ethernet1/0] llc2 receive-window 10
llc2 timer ack
Use llc2 timer ack to configure the LLC2 acknowledgment waiting time, the maximum length of time the
router waits for an acknowledgment from the peer after sending an LLC2 frame.
Use undo llc2 timer ack to restore the default.
Syntax
llc2 timer ack mseconds
undo llc2 timer ack
Default
The LLC2 acknowledgment waiting time is 200 milliseconds.
Views
Ethernet interface view
Default command level
2: System level
Parameters
mseconds: LLC2 acknowledgment waiting time in milliseconds. The range is 1 to 60000.
Examples
# Set the LLC2 acknowledgment waiting time to 10 milliseconds on Ethernet 1/0.
<Sysname> system-view
[Sysname] interface ethernet 1/0
[Sysname-Ethernet1/0] llc2 timer ack 10
267