SERVO SELECTION AND DATA SHEETS

5.6.17 Cables for Connecting PC and Servopack

5.6.17 Cables for Connecting PC and Servopack
5
338
1) Special cables for connecting a PC to a Servopack. Using these cables allows monitoring
and setting of user constants with a PC.
PC software is available for these communications. Ask your Yaskawa representative for
details. Operate the software as described in the manual supplied.
Rear of PC
D-Sub 25-pin (Male) or D-sub 9-pin (Male)
• Dimensional Drawings for Type DE9405258 (for NEC PC)
D-Sub connector 25-pin (Male) 17JE-23250-02 (D8A)
M2.6 screw
Note: Fold back the cable shielding at each end of the cable and secure it with clamps.
2) The communications specifications and connecting-circuit specifications are listed be-
low.
• Baud Rate:
9600 bps
• Number of Bits Start:
Data:
Stop:
Parity: 1 bit (even)
• Synchronization
• XON/XOFF Control
• Shift Control:
Connection Cable (2 m) (6.56 ft) or less
(6.56¦0.164)
Cable (Black) UL2921 Two M3 screws x
9−strand twisted
10 length, 0.5
(0.16 ×7) shielded
pitch
cable
1 bit
7 bits
1 bit
Start-Stop
None
None
Servopack
17LE-13090-27 (D2BC)
(Made by DDK.)
D-Sub 9-pin (Male) 17JE-23090-02 (D8B)
(Made by DDK.)
Pin Connector 17JE-23090-02 (D1)