4) The quoted allowable radial load is the value at a position 20 mm (0.79in.) from the motor
mounting surface.
5) The electromagnetic brake is only to hold the load in position and cannot be used to stop
the motor.
6) Conforms to IP55 protective structure (except connector and output shaft faces).
• 200 W (0.27HP), 300W (0.40HP), 400 W (0.53HP)
Encoder Lead
Motor Lead
Sealant
Holding Brake (deenergization
Incremental Encoder
operation)
2048 P/R
Voltage: 90 VDC
Brake holding torque = motor
rated torque
5.4 Σ -Series Dimensional Drawings
Encoder Plug
Motor Plug
Cross-section Y-Y
4-∅0.7
(4-∅0.28)
MTG Holes
Screw
Hex. nut 14
(0.55)
Shaft end screw hole
(SGMP-jjA(B)316B,
with key type only)
275
5