3.2.4 Using Contact I/O Signals

1) Contact Input Signal Terminal Connections

These signals are used to control SGDA Servopack operation. Connect these signal ter-
minals as necessary.
Note Provide an external I/O power supply separately.
There are no power terminals to which the SGDA Servopack outputs signals
externally.
External Power Supply: 24 1 VDC
50 mA or more
Yaskawa recommends that this external power supply be the same type as for the
output circuit.
→ Input +24VIN 1CN-13
This external power supply input terminal is com-
mon to the following contact input signals:
Contact Input Signals: P-CL
3.2 Setting User Constants According to Host Controller
I/O power
supply
Host controller
I/O Power Supply
(1CN-11)
N-CL
(1CN-12)
S-ON
(1CN-14)
P-CON
(1CN-15)
P-OT
(1CN-16)
N-OT
(1CN-17)
ALMRST
(1CN-18)
Servopack
Photocoupler
For Speed/Torque
Control and
Position Control
Servopack
I/O power
supply
Connect an external I/O power supply.