YASKAWA SGM series User Manual page 360

Ac servomotors and drivers
Hide thumbs Also See for SGM series:
Table of Contents

Advertisement

INSPECTION, MAINTENANCE AND TROUBLESHOOTING
6.2.1 Troubleshooting Problems with Alarm Display cont.
6
350
Cause
A
Wiring grounded between Servopack and
servomotor.
B
Servopack ambient temperature exceeds
55°C
C
Servomotor U, V, or W phase grounded.
D
• Circuit board (1PWB) defective
• Power transistor defective
E
Current feedback circuit, power transistor,
DB relay, or circuit board defective.
Display and Outputs
Digital Operator
g
p
Di
Display and
l
d
Alarm Name
Alarm Name
ALO1
A.31
ON
Position error
pulse overflow
(position control
only)
Status When Alarm Occurred
During servomotor
operation
Overflow during
high-speed opera-
tion
No feedback pulse
returned after refer-
ence pulse input.
Normal operation
but overflow when
large reference in-
put.
Check and correct wiring.
Bring Servopack ambient temperature to
55°C
Note Alarm cannot be reset while power
transistor module temperature ex-
ceeds 90°C.
Replace servomotor.
Replace Servopack.
Replace Servopack.
Alarm Output
Alarm Code Output
ALO2
ON
OFF
At power ON
A
B
F
,
C
D
E
,
,
Remedy
Alarm Output
p
ALO3
OFF
OFF: Output transistor is OFF
ON: Output transistor is ON
F