• 750 W (1.01 HP)
12 (0.47)
Sealant
Absolute Encoder
1024 P/R
Holding Brake (deenergization operation)
Voltage: 90 VDC
Brake holding torque = motor rated torque
Type
QK
U
SGMP-
08AW12B
No key
08AW14B
22
3
(0.87)
(0 8 )
(0 12)
(0.12)
08AW16B
Note
1) The detector uses a 12-bit absolute encoder 1024 P/R.
2) Type "A" indicates 200 V specification.
3) "08AW14B" and "08AW16B" have a keyed shaft. The keyway complies with JIS B
1301-1976 (precision). A straight key is supplied.
4) The quoted allowable radial load is the value at a position 35 mm (1.38 in) from the motor
mounting surface.
5) The electromagnetic brake is only to hold the load in position and cannot be used to stop
the motor.
Encoder Lead
UL20276
300¦30 (11.81¦1.18)
(35) (1.38)
Motor Lead UL2464
(35) (1.38)
300¦30 (11.81¦1.18)
180(7.09)
140(5.51)
40(1.57)
66.7(2.63)
10.5
10
3.5
(0.41)
(0.39)
(0.14)
19
(0.75)
QK
Y
Y
φ0.04
(φ0.0016)
W
T
Screw
Dimen-
sions
5
5 (0.20)
(
)
(0.20)
(0 20)
M5,
depth 8
(0.31)
5.4 Σ -Series Dimensional Drawings
Encoder Plug
Motor Plug
T
Cross-section Y-Y
j120(4.72)
(0.0016)
38(1.50)
0.04 A
0.02
4-R6
A
(0.0008)
4-φ10
(4-φ0.39)
MTG Holes
A
Shaft end screw hole
(SGMP-08AW16B,
with key type only)
Output
Approx.
Allowable
W
mass
radial
(HP)
kg
(lb)
750
6.2
392 (88)
(1 01)
(1.01)
(13 6 )
(13.67)
U
Screw
Hex. nut 17
(0.67)
φ145
(φ5.71)
5
Allowable
thrust
load
load
N (lb)
N (lb)
147 (33)
(
)
(
)
287