4) The figure below illustrates an example of operation in contact input speed control mode.
Using the soft start function reduces physical shock at speed changeover.

When Contact Input Speed Control is Used

Motor speed
Stopped
OFF
OFF
Note For the position control type, the soft start function is available only when contact
input speed control is used. The soft start function is not available when pulse ref-
erence input is used.
For the position control type, if contact input speed control mode is switched to
pulse reference input mode when the motor is running at the 1st, 2nd or 3rd
speed, the Servopack does not receive a pulse reference until positioning com-
plete signal COIN is output.
Always start outputting a pulse reference from the host controller after a position-
ing complete signal is output from the Servopack.

Signal Generation Timing for Position Control Type

Motor speed
0 r/min
COIN
Pulse reference
N-CL
P-CL
1st speed
Selected speed
The above figure illustrates signal generation timing when the soft start function is
used.
The value of t
is not influenced by use of the soft start function.
1
A maximum of 6 ms delay occurs when P-CL or N-CL signal is read.
3.2 Setting User Constants According to Host Controller
3rd speed
2nd speed
1st speed
Stopped
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
3rd speed
2nd speed
Set acceleration and
deceleration values in Cn-07
and Cn-23 (soft start time).
1st speed
2nd speed
3rd speed
ON
ON
OFF
ON
ON
OFF
ON
Pulse reference
1st speed
Stopped