Handling Of Power Loss; Alarm Traceback Data - YASKAWA SGM series User Manual

Ac servomotors and drivers
Hide thumbs Also See for SGM series:
Table of Contents

Advertisement

APPLICATIONS OF Σ-SERIES PRODUCTS

3.7.6 Handling of Power Loss

3.7.6 Handling of Power Loss
3
TERMS
134
D TGON (1CN-9)
D Status indication mode bit data
D Monitor mode Un-05 bit 4
User Constant Setting:
Memory switch Cn-01 bit 4 = 0
1) Use the following memory switch to specify whether to clear or hold a servo alarm that
occurred at power loss.
Operation to Be Performed at
Cn-01 Bit 5
Recovery from Power Loss
If the Servopack detects instantaneous voltage
drop in power supply, it outputs alarm A.F3 to pre-
vent a hazardous situation.
Select the operation to be performed when volt-
age is recovered after alarm occurrence.
Setting
Holds servo alarm even after recovery from power loss.
0
ALM output remains OFF (circuit between 1CN-34 and 1CN-35 remains open).
Clears servo alarm after recovery from power loss.
1
ALM output remains ON (circuit between 1CN-34 and 1CN-35 is closed).
2) If this memory switch is set to "1" (to clear servo alarm), power loss is not stored as alarm
traceback data.

Alarm traceback data

The SGDA Servopack stores up to 10 last alarms as alarm data. This alarm data can be
displayed with a Digital Operator. For details, refer to 4.2.1 Operation in Alarm Trace-back
Mode.
Motor
speed
Factory
For Speed/Torque Control
Setting: 0
and Position Control
Power loss
200 or
100 V
supply
Cn-01 bit 5 = 0
voltage
Cn-01 bit 5 = 1
Meaning