YASKAWA SGM series User Manual page 183

Ac servomotors and drivers
Hide thumbs Also See for SGM series:
Table of Contents

Advertisement

USING THE DIGITAL OPERATOR
4.1.4 Operation in Status Display Mode cont.
4
172
Bit Data
Power ON
Base Block
Speed Coincidence
TGON or Torque Limit Detected
(selected by Cn-01 Bit 4)
Speed Reference Input
Torque Reference Input
Description
Lit when Servopack power ON. Not lit when Servopack
power OFF.
Lit for base block. Not lit at servo ON.
Lit if motor speed reaches speed reference. Otherwise,
not lit.
Lit if motor speed exceeds preset value.
Not lit if motor speed is below preset value.
Preset value: Set in Cn-0B (20 r/min is factory setting)
Lit if Servopack internal torque reference exceeds preset
value.
Not lit if Servopack internal torque reference is below
preset value.
Preset value: Set in Cn-08, -09 (max. torque is standard
setting)
Cn-18 is preset value during 1CN-11 (P-CL ) input.
Cn-19 is preset value during 1CN-12 (N-CL ) input.
Not lit during torque control.
Lit if input speed reference exceeds preset value.
Not lit if input speed reference is below preset value.
Specified value: Set in Cn-0B (20 r/min is factory setting)
Lit if input torque reference exceeds preset value.
Not lit if input torque reference is below preset value.
Preset value: Set in Cn-0B (10% rated torque is standard
setting)