Chapter 15
<1TR ATVC>
Attention
Settings
<FXLW TMP>
Attention
Settings
<GLUTLV Y>
<GLUTLV M>
15-200
Use it to enable/disable the primary transfer ATVC retry function for initial multiple rotation.
Use it to enable/disable the primary transfer ATVC retry function for initial multiple rotation
to suit the site of installation.
The new setting will not be valid until the power switch has been turned off and then on.
0: off at all times (spare)
1: on only if H/H (default)
2: on normally
at time of shipment/upon RAM initialization: 1
Use it to change the control temperature for the pressure roller.
The new setting will not be valid until the power switch has been turned off and then on.
0: 170 deg C (default)
1: 160 deg C
2: 150 deg C
at time of shipmen/upon RAM initialization: 0
for study by design dpt
for study by design dpt
T-15-388
T-15-389
T-15-390
T-15-391
0005-6885
0005-6888
0005-7557
0005-7577