<SND RATE>
setting
<CTM S06>
range of
settings
<CTM S07>
range of
settings
<FXEX CNT>
Settings
Use it to set a compression rate for SEND RATE (i.e., when 'high' is
selected under SEND for compression rate).
0: rate of compression 1/16 [at time of shipment/after RAM initialization]
1: rate of compression 1/20
2: rate of compression 1/24
A higher rate of compression means a lower image level.
Use it to remove the password from an export file (file transmission address).
0:do not remove password from export file
1:remove password from export file.
at time of shipment/upon RAM initialization: 0
Use it to remove the source indication of the transmission password on the
Edit screen (RUI address indication).
0:do not remove source indication of transmission password on Edit screen
1:remove source indication of transmission password on Edit screen
at time of shipment/upon RAM initialization: 0
Use it to set the temperature control hysterisis width for the outside heating roller.
The outside heating roller of the machine has a low heating capacity and tends to go
on and off frequently; this mode is offered to prevent flickering.
0: hysterisis width = /+1 deg C (225 deg C /+1 deg C)
1: hysterisis width = /+2 deg C (224 deg C /+2 deg C)
2: hysterisis width = /+3.5 deg C (222.5 deg C /+3.5 deg C)
3: hysterisis width = /+4.5 deg C (221.5 deg C /+4.5 deg C)
at time of shipment/upon RAM initialization: 0