Chapter 15
15.8.1.6.4 <PO WIRE>
for the pre transfer charging wire, indicates the number of times high voltage has gone on.
Estimated life: 500,000 image
count type: type 1
15.8.1.6.5 <PRM CLN>
for the primary charging wire cleaner, indicates the number of times it has been replaced.
Estimated life: 500,000 image
count type: type 1
15.8.1.6.6 <PO CLN>
for the pre transfer charging wire cleaner, indicates the number of times it has been replaced.
Estimated life: 500,000 image
count type: type 1
15.8.1.6.7 <PRM CLN2>
for the primary charging wire cleaner 2, indicates the number of times it has been replaced.
Estimated life: 500,000 image
count type: type 1
15.8.1.6.8 <PO CLN2>
for the pre transfer charging wire cleaner2, indicates the number of times it has been replaced.
Estimated life: 500,000 image
count type: type 1
15.8.1.6.9 <PO UNIT>
for the post charging assembly, indicates the number of times it has gone on.
Estimated life: 1,000,000 image
count type: type 1
15.8.1.6.10 <PRM UNIT>
for the primary charging assembly, indicates the number of times it has gone on.
Estimated life: 1,000,000 image
count type: type 1
15.8.1.6.11 <FIX TH1>
for the fixing assembly main thermistor (TH1), indicates the number of times it has gone on in terms of the number
of sheets involved.
Estimated life: 500,000 image
count type: type 3