7.7.2. Output functions

Main function
Sub function/
Direction/
Floor
Land.call
Direction:
- Up
- Down
- Up+Dn
Land.call1
Direction:
- Up
- Down
- Up+Dn
Land.call2
Direction:
- Up
- Down
- Up+Dn
Special LC
Call floor
VIP LC
Call floor
Emerg.LC
Call floor
Car call
Call floor
Spec.out.
Car fan
Special mode
Floor
Doors
Call floor
Doors
Call floor
Doors
Call floor
Doors
-
Doors
-
Doors
-
Doors
-
Doors
-
-
-
-
135/196
Description
Acknowledgement output of "normal" landing call; see input
functions
Acknowledgement output of landing call 1; see input functions
Acknowledgement output of landing call 1; see input functions
Acknowledgement output of special landing call; see input
functions
Acknowledgement output of VIP landing call; see input functions
Acknowledgement output of emergency landing call; see input
functions
Acknowledgement output of car call; see input functions
Output for car fan
May be used as output to switch on the car fan as well as for
acknowledgement of car fan button.
More settings see „Special param." -> „Car fan"
Output is activated if lift controller is in one of the special modes:
- Special trip / VIP trip / Emergency trip
- Lift switched off
- Landing calls disabled
- Clock run