Intec MLC 8000 Operating Manual page 40

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
1. Menu level
2. Menu level
3. Menu level
4. Menu level
Forc.door cl.
Door op.push
Door state
Dynamic mode
Fire det.act.
Auto return
Run thr.fire
Last trip
Last floor
Fire evac.floors
1. F.Evac.fl.
2. F.Evac.fl.
...
40/196
Description
yes: Light screen is ignored when the door is closed; Door closes with
reduced force and speed; additionally, an audible signal sounds (if
present)
no: „Normal" door closing
Setting if door open push is still active or disabled in fire evacuation
mode
opened: door remains open after reaching the relevant floor
reclose: Upon reaching the set floor the door opens and then closes
again
yes: If the lift has already moved to a "safe" level in case of fire, but
the fire alarm is activated than in this floor, then the lift drives to
another "safe" level.
no: after moving to a "safe" level in case of fire the lift will stay in this
floor, even if the fire alarm triggers in this floor.
no: The fire alarm of the individual floors are ignored unless the input
"fire" is enabled.
yes: the fire alarm of the individual floors are evaluated regardless of
the state of the input "fire".
yes: After disabling the input "fire" (and, if parameter "Fire det .act " is
set to yes, all fire detectors on each floor; see above) the lift returns
back to normal operation.
no: The lift does not return to normal operation even after deactivation
of all fire signals.A Reset is necessary.
yes: The lift goes when needed, through the floor, where the fire alarm
is activated, to reach the nearest "safe" level.
no: The lift never goes through a floor where the fire alarm has been
activated.
yes: Even if it is not possible, according to the settings "Fire evac.
floors" (see below), to approach one of the safe floors, (f.ex. because
all fire alarms had been triggered) the lift approaches the last fire floor,
according to this setting.
Lift goes to this floor, if ther is no other safe floor avbailable (see
above).
Setting of safe floorsin case of fire
In case of fire the lift will go to this floor if possible
If it is not possible to go to the 1st fire evacuation floor in case of fire
(see above), the lift will go to this 2nd fire evacuation floor.
...