Lift controller MLC 8000
22/12/2016
Operating manual V2.0
Main function
Sub function/
Direction/
Floor
Special run
VIP run
Emerg. run
Out of work
Inspection
Inspect.Car
Inspect.Pit
Ramp drive
Buzzer
CC Buzzer
LC Buzzer
Floor
Doors
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Type:
-
-Load
-Door
-Load+Door
-Carcall
-Load+CC
-Door+CC
-Load+CC+Door
-
-
Floor
Doors
136/196
Description
Output is activated if lift controller is in Special trip mode
Output is activated if lift controller is in VIP trip mode
Output is activated if lift controller is in Emergency trip mode
"Out of work" indicator; output is activated if:
- Error state
- Doors disabled
- Maintenance count has reached its limit (see menu item
„Statistics" –> „Maint.count" and parameter „Maint.interval"
- Car calls disabled
- Landing calls disabled (only if output is programmed on an ESE
board on the shaft bus)
Additional this output is activated during normal operation:
- by settingin menu item „Test" -> „Out of work"
- by input function „Special func." -> „Out of work" (see input
functions above)
Output is activated in inspection mode (top of car or shaft pit)
Output is activated in inspection mode (top of car)
Output is activated in inspection mode (shaft pit)
Output is activated in ramp drive mode
Depending on the setting "type" the buzzer may be used for
different functions:
- as overload buzzer
- while forced door closing (Light screen ignored)
- short acoustic signal (2s) if a car call is pressed
Car call buzzer; same function like above setting "Car call"
Landing call buzzer;short acoustic signal (2s) if landing call is
pressed.