Intec MLC 8000 Operating Manual page 194

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
XL7
Flat cable connection to FVE Version 1.1 (Connector XF4) or to connect to car call boards
with flat cable connection (Fa. KLST)
1
NR
2
EAF10
3
EAF11
4
EAF12
5
EAF13
6
EAF14
7
EAF15
8
EAF16
9
GND
10
+24V
11
NL
12
+24A
13
M
14
L
XL8
1
GND
2
WAIT
3
SPEAK
4
GND
5
+24V
6
+24A
7
NR
8
NL
9
M
10
L
XL9
Connector for Software download
SD1
SD card slot
XLJ1
Jumper for CAN bus terminator
→ Jumper must be set if LCD-045 is located at the end of the CAN bus cable.
XLJ2
Jumper for setting of node ID:
Jumper set to direction of XL9: Normal operation
Jumper set to direction of XL4: Initialization mode (setting of node ID)
XLJ3
If Jumper set: LCD-057 is operated by battery buffered +24V power supply
XLJ4
Jumper set to board edge: Buzzer is controlled by LCD-057 microcontroller (Setting of
function by "Parameter" - "Special param." - "Car display" - "Buzzer")
Jumper set to connector XL4: Buzzer is controlled by output AF9 of FVE (only possible if
LCD-057 is connected by 20pole flat cable to connector XL6 of FVE)
K1
Button to active design selection menu: With this menu it is possible to select one of 4
designs saved inside LCD-057. Selection is done with button K2 (cursor up) or button K3
(cursor down), activation by pressing button K1 again.
K2
Button to activate colour selection menu. With this menu the colour of direction arrows,
floor signs and date / time may be set (blue, yellow, black, white, grey, red or green).
Additionally it can be selected if the direction arrows should scroll if the lift is moving.
Selection of a menu item is done by pressing button K3 (cursor down), changing of
selected setting is done by pressing button K1. Activation of settings is done by pressing
button K2 again.
K3
Button to navigate inside menus (cursor down, see above)
LED
LED "Software is running"
Characteristics and features:
-
Car level display - LCD graphic display with 640*480 Pixeln, 24 Bit colour depth
-
replaced Emergency light board TVE by additional connectors
Alarm call car operation panel COP
7 connected inputs / outputs of FVE (E10-E16 and A10-A16
0V switching)
0V power
+24V power
Emergency light car operation panel COP (output A7 FVE)
Battery buffered 24V power
Intercom microphone
Intercom loudspeaker
0V power supply
Signal from emergency telephone to display "Please wait"
Signal from emergency telephone to display "Please speak"
0V power supply
+24V power supply
Battery buffered +24V power supply
Alarm call car operation panel COP
Alarm call car operation panel COP (output A7 of FVE)
Intercom microphone
Intercom loudspeaker

Hide quick links: