Intec MLC 8000 Operating Manual page 66

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
1. Menu level
2. Menu level
RS232
Save parameters
Node ID
Node ID TSE
Node ID ESE
Node ID ASE
Node ID PSE
Node ID Simul.
Load weighing
Analog inp.
3. Menu level
4. Menu level
WAIT
OK
0
1 0 1 0
1 0 1
Example:
RS232
CONNECTED
NOTHING
3
1 0 1 0
1 0 1
Node ID
Initialization
Node ID
Branch No.
Initialization
Adjust sensor
Meas.value:
66/196
4th line: module signals (from left):
Incoming call RI | CTS input | Input DCD | DSR input |
Reset output | RTS output | DTR output
Hardwaretest D-Sub interface (RS232)
st
1
line: Parameterized connection type (RS232 / modem)
nd
2
4th line: module signals (from left):
Incoming call RI | CTS input | Input DCD | DSR input |
Reset output | RTS output | DTR output
Saving all controller parameters
If modified parameters are not saved, then during a reset / turn on / off
power supply, all previous changes will be lost.
Setting the node ID of a car panel unit TSE
Setting the node ID of a landing panel unit ESE
Initialization of a PCB (UEA) as drive control unit ASE
Initialization of a PCB (UEA) as positioning unit PSE
Initialization of a PCB (UEA) as simulation unit for test purposes
Mechanical adjustment of the load sensor (only when connected
directly to the analog load sensor input of FVE)
■■■
The load sensor should be adjusted in a way that the measured value
is about 20...40% by empty car (if the sensor value increases by higher
34%
load) or about 60...80% (in case the sensor value decreases by higher
Description
line: Last command to the module
3rd line left: Modem state
3rd line right: Monitoring time
Input of node ID of TSE
Start of Initialization
Input of node ID of ESE
New branch number of ESE
Start of Initialization
Settings for analog sensor