1. Menu level
2. Menu level
3. Menu level
4. Menu level
Qu.delay[ms]
Qui.door[mm]
Vent.time[s]
Relev.[ms]
Speeds
Speed signals
vRL
V0
V1
V2
V3
vI
vIS
vR
vRS
vEE(UPS)
vHu
vHd
vZ1
vZ2
Drive specific
22/196
Description
Waiting time between starting of door closing and starting the quick
start procedure (drive on).
If the lift is equipped with a CANopen Lift door this parameter may be
set to 0 (see also next parameter below).
Only if the lift is equipped with CANopen lift doors: Door position
where Quick start is activated
Switch off delay of car ventilatorafter trip end
Delay time for relevelling [ms].
Relevelling is only started if cabin is outside level zone for this time.
So, a possible oscillation of the cabin is avoided at the flush position.
Only for CANopen lift drives:
With this parameters the actual lift speed in mm/s is assigned to the
different functional speeds:
For all other drives:
With this parameters it is defined which speed signal outputs will be
set for the different functional speeds:
Re-levelling speed
Arrival speed
Intermadiate speed 1 (for short floor distances)
Intermadiate speed 2 (for short floor distances)
Nominal speed
Normal Inspection speed
Slow Inspection speed
Fast Electrical recall operation speed
Slow ( normal) Electrical recall operation speed
Evacuation speed (UPS-Evacuation)
Lift with holding bolts: Up speed from holding bolts
Lift with holding bolts: Down speed to holding bolts
Additional intermadiate speed 1
Additional intermadiate speed 2
Menu item only for CANopen Liift drives: Here you can directly set
parameters of the drive (usually VVVF).
The meaning of each parameter is in the operating manual of the drive.