Nr.
Error message
161/15
CAN:TimeoutReady
161/16
CAN:Timeout Br=0
161/17
CAN:TimeoutRdy=0
161/18
RDY signal off
161/19
RDY signal on
161/20
RDY signal n.ff
161/21
CAN:TimeoutOpDis
161/22
CAN:TimeoutOpEn
161/23
CAN:Timeout Move
161/24
CAN:Timeout Targ
162/0
Contactor not on
162/1
Contact. not off
163/0
Brake not opened
Description
Only by drives according to
CANopen lift DSP417:
No CAN message "Ready=1"
("Ready to switch on") in time.
Only by drives according to
CANopen lift DSP417:
No message to close the brake
("Speed zero") in time.
Only by drives according to
CANopen lift DSP417:
No CAN message "Ready=0"
("Operation disabled") in time.
The "RDY" signal from the
drive is deactivated while the
lift is moving.
The "RDY" signal from the
drive is activated while the lift is
in standstill state.
The "RDY" signal from the
drive is not activated in time.
Only by drives according to
CANopen lift DSP417:
No CAN message to stop
oparation ("Operation
disabled") in time.
Only by drives according to
CANopen lift DSP417:
No CAN message to start
moving ("Operation enabled")
in time.
Only by drives according to
CANopen lift DSP417:
No CAN message that lift
started moving ("No speed
zero") in time.
Only by drives according to
CANopen lift DSP417:
No acknowledge CAN
message for new target in time
(only in "Position mode")
Running contactors are not
switched on while starting a trip
or suddently switched off while
moving.
Running contactors are not
switched off on trip end.
Brakes are not opened while
97/196
Lift controller reaction
Emergency stop.
Back to normal operation inside 2
seconds.
Emergency stop.
Back to normal operation inside 2
seconds.
Emergency stop.
Back to normal operation inside 2
seconds.
Emergency stop.
Back to normal operation inside 2
seconds.
Back to normal operation if the
signal is deactivated.
Emergency stop.
Back to normal operation inside 2
seconds.
Emergency stop.
Back to normal operation inside 2
seconds.
Emergency stop.
Back to normal operation inside 2
seconds.
Emergency stop.
Back to normal operation inside 2
seconds.
Emergency stop.
Back to normal operation inside 2
seconds.
Emergency stop.
Back to normal operation inside 2
seconds.
Back to normal operation if all
running contactors are switched
off.
Emergency stop.