Main function
Sub function/
Direction/
Floor
Call config.
Test runs
Dr. lock test
Car empty
Group off
Standby
Forc.stop off
Telec.off
Roll.text
Attend.funct.
Car attend.
Car att.push
Car att.off
Call dir.up
Call dir.down
Floor
Doors
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Signal no.
-
-
-
-
-
-
-
-
-
-
-
126/196
Description
For safety reason it is possible to use 2 (or more) inputs (with different "Signal
no.) In this case the lift controllers checks if all inputs are switched at the same
time.
Input to activate "Call configuration mode"
See also "General param." - "Call config."
Input to activate test runs
If the input "Door lock test" is avtivated, the lift always stops above floor limit in
each floor (in top floor below floor limit) depending of the setting "Lockt.[mm]".
In this way it is possible to check the shaft door lock in each floor (requirement
in Austria)
Sensor if car is empty
Required for "Call configuration mode" to switch from 1 configuration to next.
Input to separate a group of lifts into single lifts.
Note: For this function it is necessary to have at least 2 separate shaft bus cables
with bus coupler CBC.
Activation of standby mode (for VVVF)
Note: The VVVF must either have an input to activate standby function or must
be connected by CANopen lift.
Input for enabling the lift after a forced stop (see "Special param." - "Forced
stop")
Deactivation of all special functions initiated by remote control
With this signal one of three special texts (if using PMA) or pictures (if using
LCD-047 or LCD-057) are activated on the display.
This text or pictures must be pre-defined and programmed by INTEC GmbH (if
using PMA) or may be created by PC software "LCDDesign" and downloaded to
LCD-047 or LCD-057.
The input function may be programmed to any input of the PMA, LCD-047 or
LCD-057.
Activation/Deactivation of attendance mode (lift operator) by switch
Activation/Deactivation of attendance mode (lift operator) by push
Push to deactivate attendance mode.
This input can't be used to activate attendance mode
Button to select next travel direction
See above