Intec MLC 8000 Operating Manual page 145

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
Main function
Sub function/
Direction/
Floor
- Green
Pre-Traffic
- Red
- Green
Drive
Running cont
Fast cont.
Slow cont.
- Up cont.
- Down cont.
Brake cont.
- Star cont.
- Delta cont.
- Direction up
- Direction dn
- Speed sig.1
- Speed sig.2
- Speed sig.3
- Speed sig.4
- Speed sig.5
- Speed sig.6
- Speed sig.7
- Speed sig.8
Enable drive
Startsignal
Valve(delay)
Floor
Doors
Floor
Doors
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Dir.
-
-
-
-
-
-
-
145/196
Description
Outputs for controlling a right of way traffic light for a car lift. The
green light switches on if the lift moves into a floor or is already in
one floor and no other vehicle is inside the lift.
The green light indicates a waiting driver that he can already drive
up to the shaft door.
Output for the running contactor.
Output for the fast speed contactor.
Output for the slow speed contactor.
Output for the upward or downward contactor.
Output for the brake contactor.
Output for the star and delta contactor.
Direction signal Upward / Downward for the drive
Speed signals for speed selection of the drive.
The selection which speed signal is set for which lift speed is
defined with setting of the parameters
„Speed signals" (see chapter "Parameters" above).
With setting of „Dir." it may be selected if this speed signal output
should be set in both direction (mainly by VVVF drives) or only in
one direction (e.g. for hydraulic control board "Bucher" or
"Beringer")
Enable signal for drive
Start signal for drive
Control output for delayed switch off the valve (while stopping first
pump motor is switched off; than after a programmed time (see
drive parameter) the valve is switched off.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents