Intec MLC 8000 Operating Manual page 172

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
Position
Terminal no.
Description
XF8
1
+24V
2
GND
3
SU
4
+24A
5
GND
6
SM
7
+24V
8
GND
9
SO
10
GND
11
VO
12
GND
13
VU
XF9
1
NR
2
GND
3
NL
4
+24A
5
L
6
M
7
+24A
8
CH+
9
CH-
10
GND
XF10
1
EAF9
2
EAF10
3
EAF11
4
EAF12
5
EAF13
6
EAF14
7
EAF15
8
GND
9
+24V
XF11
1
NC
2
COM
3
NO
XF12
1
KF4.S
2
KF3.S
3
KF3/4
4
GND
5
EF8
6
GND
7
EF7
8
GND
9
EF6
10
GND
11
EF5
XF13
1
KF2.S
2
KF1.S
Function
Input E25 and 24V power supply, free programmable, default: lower door
zone switch SGU
Input and battery buffered +24V power supply for door zone switch SGM
Input E24 and 24V power supply, free programmable, default: upper door
zone switch SGO
Input E26 and 0V power supply, free programmable, default: upper prelimit
switch VO
Input E27 and 0V power supply, free programmable, default: lower prelimit
switch VO
Alarm call input from car operation panel COP
Emergency light output A7
Connection for Intercom in car operation panel COP(Microphone,
Loudspeaker, battery buffered +24V power supply)
Control bus (CAN Bus 1) – High signal for car operation panel COP
Control bus (CAN Bus 1) – Low signal for car operation panel COP
0V - connector for cable shield to car operation panel COP
7 Inputs / Outputs E9 to E15 / A9 to A15, free programmable, low active
0V power supply for Inputs E9-E15
+24V power supply for Outputs A9-A15
Potential free changeover contact of alarm call relay KF7
Relay KF4 (A4), N.O. contact, free programmable, default: Door close relay
door 2
Relay KF3 (A3), N.O. contact, free programmable, default: Door open relay
door 2
Common for N.O. contact relays KF3 and KF4
Input E8 and 0V power supply, free programmable, default: Light screen
door 2
Input E7 and 0V power supply, free programmable, default: Reverse switch
door 2 (mechanical obstacle)
Input E6 and 0V power supply, free programmable, default: Door closed
limit switch door 2
Input E5 and 0V power supply, free programmable, default: Door opened
limit switch door 2
Relay KF2 (A2), N.O. contact, free programmable, default: Door close relay
door 1
Relay KF1 (A1), N.O. contact, free programmable, default: Door open relay
door 1