Intec MLC 8000 Operating Manual page 41

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
1. Menu level
2. Menu level
3. Menu level
4. Menu level
Firemen run adj.
Door cl.
Door op.
Door firefl.
Retrieve car
Autofiremode
Auto-normal
Hazardous goods
Car calls
Car fan
Fireman mode
41/196
Description
Parameter for fireman trip
Operation of the door closing in fireman mode:
auto: The door closes automatically to start a trip
pulse: The door is not closed until the close-door-button was pressed
shortly.
stop: The door is closed only when the door-close-button is pressed
and held down. Releasing the button stops the door.
reverse: Door is closed only when the door-close-button is pressed
and held. When releasing the button, the door opens again as long as
she was not completely closed
See above; handling of door opening
Operation of the door (opening and closing) in fireman floor (main
floor):
auto:In the fireman floor the door opens and closes during firefighting
operation alwaysautomaticallyl, regardless of the settings described
above.
fire: In the fireman floor the door opens and closes like defined in the
above setting for all other floors (auto/pulse/stop/reverse).
yes: if the lift is already in the fire service operation, the lift can be
called back by re-activating the fire call in the fireman floor.
no: The lift can not be called back into the fireman floor once fire
operation has been started.
yes: After reaching the fireman floor the lift will go to fireman
operation automatically.
no: To start fireman operation a separate key switch is necessary
inside car panel.
Indicates whether the lift (if fire brigade call is available after returning
to the fire floor) returns to normal operation after turning off the
fireman key switch. If "No", a reset is required.
yes: Targeted selection is done via car calls
No: Separate hazardous calls are necessary.
normal: cabin fan works even when transporting dangerous goods as
in the default mode.
always: During a hazardous transport, the cabin fan is running
constantly
Never: During a hazardous transport, the cabin fan is always off.
yes: Fireman service has higher priority than hazardous transportation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents