Main function
Sub function/
Direction/
Floor
Call bypass
LC bypass
Ignore LC
LC off push
Fire control
Firemen run
Fire call
Fire evac.
Fire alarm
Fire return
UPS Evacuat.
UPS evac.
UPS-brake
Evac.active
Evac.enable
Evac.normal
Evacuation
Evac.active
Ev.enable CC
Evac.stopped
Disable CC
Floor
Enable CC
Floor
Disable LC
Dir.:
Floor
Doors
-
-
-
-
-
-
-
-
-
-
Floor
Doors
Signal no.
-
Floor
-
-
-
-
-
-
-
Evac.floor
Doors
-
-
-
-
-
-
-
-
-
-
-
Doors
-
Doors
Floor
Doors
127/196
Description
Call of actual floor is ignored as long as the button is pressed
Button to ignore landing calls. If lift stops in a floor landing calls are enabled
automatically.
Switch to ignore landing calls
Button to clear and disable landing calls. If lift stops in a floor landing calls are
enabled automatically.
Activation of fire department trip
If this input is activated, the lift goes immediately to the programmed fire
evacuation floor and opens the defined doors. Lift goes out of operation and
door remain open.
General fire detector
Note: With setting of "Signal no." up to 8 inputs may be programmed as "Fire
evac"
Fire detector in specific floor
Input to return to normal operation even if fire
Evacuation by UPS to next floor (depending onstate of input "Half load" - if
exists)
See also "Special param." - "Evacuation"
Emergency evacuation by manual brake opening.
If this input is activated the HSE changes to state display with actual speed (bar
graph) and direction.
Evacuation trip to the evacuation floor; programmeddoors will be opened.
See also "Special param." - "Evacuation"
Stat signal for evacuation trip
(for evacuation sequence of several lifts).
Input to switch back to normal operation even if "Evac.active" input is set.
Input to start evacuation mode according to EN81-76
Input for enabling car calls in evacuation mode
Input to stop evacuation mode
Input to disable car calls for specified floor and doors.
Input to enable car calls for specified floor and doors.
Input to disable landing calls for specified floor and doors.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents