Intec MLC 8000 Operating Manual page 24

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
1. Menu level
2. Menu level
3. Menu level
Floor positions
Floor distances
Floor height
SGM Positionen
4. Menu level
Minimum distance between start and target floor to start with reduced
Min.Dist.v1
Minimum distance between start and target floor to start with reduced
Min.Dist.vZ2
Minimum distance between start and target floor to start with reduced
Min.Dist.vZ1
Dec. vI ↑
Dec. vI ↓
Stop vI ↑
Stop vI ↓
Stop vN ↑
Stop vN ↓
Stop vAh
Stopping distance if moving with vAs in downward direction (lift with
Stop vAs
Fl. 1- 2
Fl. 2- 3
...
1.Floor
2.Floor
...
1.Floor ↑
1.Floor ↓
2.Floor ↑
24/196
Description
speed v2
speed v1
speed vZ2
speed vZ1
Braking distance for inspection speed vI in the upward direction
Braking distance for inspection speed vI in the downward direction
Stopping distance for inspection speed in the upward direction
Stopping distance for inspection speed in the downward direction
Stopping distance for relevelling speed in the upward direction
Stopping distance for relevelling speed in the downward direction
Stopping distance if moving with vAh in upward direction (lift with
holding bolts
holding bolts
Distance between 2 floors
Absolute floor position
B ottom floor = 0
Measured switching points of the door zone switch SGM
switching point above 1st floor
switching point below 1st floor
...