4.14 Error messages

Nr.
Error message
16/1
AWG Band decekt
32/112
Pos. Defect
32/112
AWG defect
49/0
Phase off
49/1
Car light off
50/0
Accu power
52/0
SL off
52/1
SL off trip
52/2
SL door off
52/3
SL final limit
Description
magnetic tape of the absolute
encoder AWG defective
Defective positioning system
positioning system (absolute
encoder AWG) defective
Phase error (signal of an
external power supply monitor
device)
Car light power supply is
missing
24V power supply off. All other
errors are ignored in this state.
Safety line open due to a fault.
Safety line open due to a fault
while the lift was moving.
Safety line of revolving shaft
door, car door or automatic
shaft door is missing while the
lift wants to start a trip.
Lift (probably) in final bottom
limit switch.
The error message is
generated when the primary
safety circuit is missing, while
the lift is above top floor level
or below bottom floor level (see
parameters "Top limit" and
"Bot.limit" in "General
89/196
Lift controller reaction
Check tape and change if
necessary.
For a detailed error analysis see
manual of AWG
Emergency stop
This error message appears, for
example, if the magnetic tape of
the AWG is torn.
Emergency stop
Lift continues operation if AWG
has reset the error.
For a detailed error analysis see
manual of AWG.
Emergency stop; then out of
service
Rope lift: Stop in next floor
Hydraulic lift: Trip to lowest floor
Return to normal operation when
car light power is on again.
Emergency stop, , then error state.
Automatic return to normal
operation when power is on.
Error state "SL off".
Automatic return to normal
operation when the safety circuit is
closed again.
Emergency stop; then error state
"SL off".
Automatic return to normal
operation when the safety circuit is
closed again.
Waiting time of 4 seconds, then lift
controller opens the doors and
closes again.
Rope lift: Back to normal operation
if limit switch is closed.
Hydraulic lift: If safety line is closed
again lift goes to lowest floor and
stops operation.