Intec MLC 8000 Operating Manual page 193

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
Position
Pin
Function
XL1
1
+24V
2
0(24V)
3
CAN+
4
CAN-
XL2
1
0(24V)
2
D1
3
D2
4
D3
5
D4
6
D5
7
D6
8
D7
9
D8
10
+24V
XL3
1
D1
2
D2
3
D3
4
D4
5
D5
6
D6
7
D7
8
D8
9
0(24V)
10
+24V
XL4
1
KT1C
2
KT1O
3
KT1S
XL5
1
+24A
2
0(24V)
3
CH+
4
CH-
XL6
Flat cable connection to FVE Version 1.2 (see description of FVE 1.2, connector XF20
1
NR
2
EAF9
3
EAF10
4
EAF11
5
EAF12
6
EAF13
7
EAF14
8
EAF15
9
EAF16
10
+24A
11
+24V
12
GND
13
+24V
14
NL
15
+24A
16
M
17
L
18
CH+
19
CH-
20
GND
+24V Power supply input
0V Power supply input
CAN-Bus – High signal
CAN-Bus – Low signal
0V Power supply for inputs / outputs
8 inputs / outputs E1-E8 and A1-A8, low active, free programmable.
Connector XL2 is in parallel to XL3 (same inputs/outputs)
+24V Power supply for inputs / outputs
8 inputs / outputs E1-E8 and A1-A8, low active, free programmable.
Connector XL3 is in parallel to XL2 (same inputs/outputs)
0V Power supply for inputs / outputs
+24V Power supply for inputs / outputs
Alarm relay common
N.C. contact
N.O. contact
Connector for handheld terminal (battery buffered 24V power supply)
Connector for handheld terminal (0V power supply)
Connector for handheld terminal (CAN bus high signal)
Connector for handheld terminal (CAN bus high signal)
Alarm call
8 connected inputs / outputs of FVE (E9-E16 and A9-A16
0V switching)
Connector 2 (EAF9) is connected with the onboard buzzer of LCD-057
Battery buffered 24V power
+24V power
0V power
+24V power
Emergency light car operation panel COP (from output A7 FVE)
Battery buffered 24V power
Intercom microphone
Intercom loudspeaker
CAN-Bus – High signal
CAN-Bus – Low signal
0V power