Intec MLC 8000 Operating Manual page 166

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
Position
Terminal no.,
Description
3
KF1.S
4
KF2.C
5
KF2.S
6
KF3.C
7
KF3.S
8
KF4.C
9
KF4.S
10
+24V
XF4
1
NR
2
EAF10
3
EAF11
4
EAF12
5
EAF13
6
EAF14
7
EAF15
8
EAF16
9
0(24V)
10
+24V
11
NL
12
+24A
13
M
14
L
XF5
1
+24A
2
SM
Nur
3
SU
FVE1.1
4
SO
5
VO
6
VU
7
0(24V)
8
0(24V)
9
+24V
10
+24V
XF6
1
CH+
2
CH-
3
0(24V)
XF7
1
NO
Only
2
COM
FVE2.1
3
NC
XF7.1
1
+24V
2
0(24V)
3
Res1
4
Res2
5
Res3
6
Res4
7
Res5
8
Res6
XF7.2
1
0(24V)
2
VU
Function
Door open relay door 1
Door relay KF2 (Output 2 FVE), N.O. contact, free programmable, default:
Door close relay door 1
Door relay KF3 (Output 3 FVE), N.O. contact, free programmable, default:
Door open relay door 2
Door relay KF4 (Output 4 FVE), N.O. contact, free programmable, default:
Door close relay door 2
24V power supply, mainly used for external door relays or door controller
Alarm call car operation panel COP (for flat cable connection of COP)
7 Inputs/Outputs E10-E16 and A10-A16
Low active, mainly for car operation panel COP (for flat cable connection of
COP)
Note: Inputs/outputs are also available on connector XF11
0V – power supply for car operation panel COP (for flat cable connection of
COP)
+24V power supply for car operation panel COP (for flat cable connection of
COP)
Emergency light in car operation panel COP (FVE output A7, for flat cable
connection of COP)
Battery buffered +24V power supply for car operation panel COP (for flat cable
connection of COP)
Intercom microphone (for flat cable connection of COP)
Intercom loudspeaker (for flat cable connection of COP)
Battery buffered 24V power supply for Position unit KLST GmbH (flat cable)
Door zone switch SGM of Position unit KLST GmbH (flat cable)
Inputs E25, E24, E26, E27 (low active), for door zone switches SGU and SGO
and for prelimit switches VO and VU (Position unit KLST GmbH over flat cable)
0V power supply for Position unit KLST GmbH (flat cable)
24V power supply for Position unit KLST GmbH (flat cable)
Control bus (CAN Bus 1) – High signal trailing cable
Control bus (CAN Bus 1) – Low signal trailing cable
0V – power supply for shield of CAN bus cable (trailing cable)
Alarm relay - N.O. contact
Alarm relay - Common
Alarm relay - N.C. contact
+24V power supply, for additional components
0V – power supply
Free connectors for additional trailing cable wires; onboard connected to
XF1.Res1-6
Input E27 and 0V (Common) for lower prelimit switch VU

Hide quick links: