Intec MLC 8000 Operating Manual page 176

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
XU6
Pin1
LED
UEA.2 Hardware-Version 2.0
Position
Pin
Function
XU1
1
+24V
2
0(24V)
3
CAN+
4
CAN-
XU2
1
0(24V)
2
D1
3
D2
4
D3
5
D4
6
D5
7
D6
8
D7
9
D8
10
+24V
XU3
1
D1
2
D2
3
D3
4
D4
5
D5
6
D6
7
D7
8
D8
9
0(24V)
10
+24V
XU4
Connector for plugging UEA on HSE, FVE or TVE
1
Pin1
2
+24V
3
0(24V)
4
CAN+
5
CAN-
6
Pin6
XU5
Connector for Software download
XU4
XU7
Pin1
Pin1
Pn2
Pin1
+24V Power supply input
0V Power supply input
CAN-Bus – High signal
CAN-Bus – Low signal
0V Power supply for inputs / outputs
8 inputs / outputs E1-E8 and A1-A8, low active (UEA.1) or high active
(UEA.2), free programmable.
Connector XU2 is in parallel to XU3 (same inputs/outputs)
+24V Power supply for inputs / outputs
8 inputs / outputs E1-E8 and A1-A8, low active (UEA.1) or high active
(UEA.2), free programmable.
Connector XU3 is in parallel to XU2 (same inputs/outputs)
0V Power supply for inputs / outputs
+24V Power supply for inputs / outputs
Not used (closed to protect against incorrect connection)
+24V Power supply input
0V Power supply input
CAN-Bus – High signal
CAN-Bus – Low signal
Not used (closed to protect against incorrect connection)
XU4
XU6
Pin1
Pin1
LED
UEA.1 Hardware-Version 2.0
XU7
Pin1
Pn2
Pin1