Nr.
Error message
242/7
243/7
241/8
Door x light scr.
242/8
243/8
241/9
Door x rev. input
242/9
243/9
241/10
Door x wrong fl.
242/10
243/10
Exxx
Unknown err.
Description
a permanently interrupted light
screen (only if parameter
"Nudging" is set)
Light screen permanently
interrupted (parameter "Max.
LS [s]")
Door reverse input (mechanical
blocking signal) permanently
interrupted
Only for electrical operated
shaft doors with limit switches:
Door open limit switch is
operated in other floor (maybe
shaft door in any other than the
actual floor is open)
Error code of an external CAN
open module (e.g. VVVF
Zetadyn with CANopen
connection)
An error code has been sent by
an external CAN open module,
which is not yet described
inside the lift controller.
106/196
Lift controller reaction
reduced force. If available the
buzzer signal is switched on while
door is closing
If nudging is enabled (see above)
forced door closing
Back to normal operation if reverse
input is off.
Out of operation
Back to normal operation if this
shaft door is closed again
See operation manual of this
device
See operation manual of this
device