1. Menu level
2. Menu level
Temp.sensor
Internal Param.
3. Menu level
4. Menu level
Overl[kg]
Min.temp
Min.Limit[°C]
Max.temp
Max.Limit[°C]
Cooling [°C]
Empty load
100% load
Startpos.
Count dir.
Doorzone> >SGM
Min. Doorzone>
Inc.by accu
AWG1-2[mm]
Pos.mode[mm]
58/196
Description
Starting this value is detected as overload.
Setting this value to 0, the overload detection is disabled.
Settings for temperature sensor on HSE board (only HSE version 1.05
and newer)
Use temperature sensor for checking minimum machine room
temperature
Minimum temperature in °C
Use temperature sensor for checking maximum machine room
temperature
Maximum temperature in °C
Temperature level to switch on cooling (Special output-cooling; e.g.
for control cabinet fan)
All red values are system parameters and should be changed only in
exceptional cases by specialists.
Analog value of the load sensor in an empty car.
Analog value of the load sensor with a full car (rated load).
Internal starting value for position count
Counting direction of the position sensor (Encoder)
Simulation of the door zone switch by controlling (distance between
the simulated signal SGO and SGU and switching point SGM)
Settings for lifts with very short floor distances (<300mm approx): If
the floor distance is less than the this value, then the two floors have a
common door zone; which means, the door zone between the two
floors is not switched off (both "real" door zone switch as well as
simulated by the lift controller or "Double-AWG" door zone switch)
Setting if the incremental position encoder is buffered by battery
voltage or not. If set to "No", a new calibration trip (reset trip) takes
place (to the reference switch SGE) if the mains supply was switched
off. If set to "Yes", it is assumed that the incremental encoder counts
up even during a power failure and thus a new calibration run is not
required.
In case of usage a "Double AWG" for positioning: distance between
the two position units and thus the difference in the measured
position.
Only for operation of a CANopen Lift frequency inverter in "Position
mode": distance from the required braking point when entering a level
in which the targeted floors can still be changed.