Intec MLC 8000 Operating Manual page 31

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
1. Menu level
2. Menu level
ESE disp.alloc.
Mandatory PCBs
HSE in-/outputs
3. Menu level
4. Menu level
1.Floor
2.Floor
...
ESE 1.1 Lift
...
ESE64.8 Lift
Mandatory TSE
TSE 1
TSE 2
...
Mandatory -ESE
ESE 1.1
ESE 1.2
...
ESE 64.8
HSE Inputs
1:
...
15:
HSE Outputs
1:
...
31/196
Description
1st floor designation (eg, 'GF' or '0')
2nd floor designation
Assignment of a floor level indicator to one of the lifts inside a lift
group.
Specifies, from which Lift the actual floor position is displayed at the
floor level indicator with node ID 1, branch number 1 (ESE1.1)
...
Specifies, from which Lift the actual floor position is displayed at the
floor level indicator with node ID 64, branch number 8 (ESE64.8)
Setting, which TSE or ESE modules are necessary for the operation of
the lift
If set to "Yes" the lift goes to error state ("PCB fault") if the TSE1 does
not work or does not exist. If set to "No," the lift continues operation
even without TSE1 and only a warning ("Maintenance") flashes in the
display.
See TSE above
Function of the inputs and outputs of the mainboard HSE
Function of input 1 of HSE
...
Function of input 15 of HSE
Function of output 1 of HSE
...