Functions For Free Programmable Inputs And Outputs; Input Functions - Intec MLC 8000 Operating Manual

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0

7.7 Functions for free programmable inputs and outputs

7.7.1. Input functions

Main function
Sub function/
Direction/
Floor
Land.call
Direction:
- Up
- Down
- Up+Dn
Land.call1
Direction:
- Up
- Down
- Up+Dn
Land.call2
Direction:
- Up
- Down
- Up+Dn
Special LC
Call floor
VIP LC
Call floor
Emerg.LC
Call floor
Car call
Call floor
Spec.funct.
Car fan
Special run
VIP run
Floor
Doors
Call floor
Doors
Call floor
Doors
Call floor
Doors
-
Doors
-
Doors
-
Doors
-
Doors
-
-
-
-
-
-
123/196
Description
„normal" landing call
Mainly used for landing calls inside a group of lift, if a landing call should call
any special lift.
Example: In a lift group just 1 lift goes to lowest floor. Normally it doesn't matter
for a user which lift will serve a landing call. But if the user wants to go to lowest
floor it is important that just that 1 lift serves the floor. This additional landing
call should be programmed as Land.call1.
See above
Special landing call (Landing call with higher priority than "normal" landing call
VIP landing call (Landing call with higher priority than special landing call
Emergency landing call (Landing call with higher priority than VIP landing call
„normal" car call
Car fan push
More settings see "Special param." - "Car fan"
Special run (landing calls off - only car calls active)
More settings see „Special param." – "Special run adj."
VIP run (landing calls off - only car calls active)
More settings see „Special param." – "VIP run adj."

Hide quick links: