Intec MLC 8000 Operating Manual page 102

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
Nr.
Error message
176/21
Slick error
176/22
AWG2 CAN fault
176/23
AWG2 error
176/24
Shelter top open
176/25
Shelter bot.open
176/26
Bearer top off
176/27
Bearer top on
176/28
Bearer bot.off
176/29
Bearer bot.on
176/30
Shelter open
176/31
Apron off
176/32
Apron not off
176/48
Interm.door
Description
sequence in lift schematic).
A possible reason is also, that
one of the door zone switches
did not switch off.
For lifts with slip monitoring:
slip too large
Bei Aufzügen mit
Schlupfüberwachung: Schlupf
zu groß
CAN bus connection to 2. AWG
disturbed
Fault signal from control unit
(UEA) if using double AWG
Shelter monitoring in shaft
head triggered
Shelter monitoring in shaft pit
triggered
Input signal from automatic
bearer in shaft head not
switched on while control
output for bearer is set.
Input signal from automatic
bearer in shaft head still
switched on while control
output for bearer is off.
Input signal from automatic
bearer in shaft pit not switched
on while control output for
bearer is set.
Input signal from automatic
bearer in shaft pit still switched
on while control output for
bearer is off.
Shelter monitoring triggered
Apron is pulled out even if it
should be pulled in (depending
on actual lift position and type
of apron)
Apron is not pulled out even if it
should be (depending on actual
lift position and type of apron)
Intermediate door opened while
lift was moving
102/196
Lift controller reaction
state again (see switching
sequence diagram in lift
schematic).
Check all position switches.
Emergency stop, than out of
operation
Emergency stop
Back to normal operation if CAN
bus connection works again
Stop in next floor, than out of
operation
Only moving with inspection /
emergency recall operation
possible; otherwise emergency
stop
See above
Emergency stop, than out of order.
Back to normal operation if input is
switched on
Emergency stop, than out of order.
Back to normal operation if input is
switched off
See above
See above
Only moving with inspection /
emergency recall operation
possible; otherwise emergency
stop
Emergency stop, than out of order.
Back to normal operation if apron
has right state again.
Emergency stop, than out of order.
Back to normal operation if apron
has right state again.
No further reaction.
Only for information or for better